Figure 9 plots the performance of the passive
measurement scheme for three different values of the parameter
. These correspond to assigning 80%, 50% and 20% weight to
the current measurement sample and the remaining weight to the past
samples. Although we only show results for a sampling interval of 30s,
the performance from other interval sizes are similar. The figure also
plots the performance when no history is employed (
) and
the performance from using ISP 3 alone. Notice that the performance
from employing history is uniformly inferior in all situations,
relative to employing no history. In fact, historical samples only
serve to bring performance close to that from using the single best
provider. These results show that the best way to estimate provider
performance is to just use the current performance sample as an
estimate of near-term performance.